Nachträgliche Verstärkung von Spannbetonbrücken im Koppelfugenbereich mit bewehrten Betonlaschen.

Translated title of the contribution: Subsequent Strengthening of Prestressed Concrete Bridges at the Tendon Coupling Joints with Reinforced Concrete Connectors.
  • Gert Koenig*
  • , Horst Dietrich Quitmann
  • , Joerg Stuelb
  • , Helmut Weigler
  • *Corresponding author for this work

    Research output: Journal contributionsJournal articlesResearchpeer-review

    Abstract

    It is proposed that the tensile flanges be strengthened by means of reinforced concrete connector units, with dowel bolts as additional anchorage elements to ensure permanent bond and composite action also under not predominantly static loads. The effectiveness of the technique as a whole has been confirmed experimentally.

    Translated title of the contributionSubsequent Strengthening of Prestressed Concrete Bridges at the Tendon Coupling Joints with Reinforced Concrete Connectors.
    Original languageGerman
    JournalBeton- und Stahlbetonbau
    Volume75
    Issue number10
    Pages (from-to)229-235
    Number of pages7
    ISSN0005-9900
    DOIs
    Publication statusPublished - 10.1980

    Research areas and keywords

    • Construction engineering and architecture

    ASJC Scopus Subject Areas

    • Building and Construction

    Fingerprint

    Dive into the research topics of 'Subsequent Strengthening of Prestressed Concrete Bridges at the Tendon Coupling Joints with Reinforced Concrete Connectors.'. Together they form a unique fingerprint.