Reliability and device objectivity in oscillatory blood pressure measurement – a measurement error analysis to inform clinical decision making

  • Konstantin Warneke
  • , Niklas Lebelt*
  • , Franz Liebermann
  • , Benjamin Jöst
  • , Marco Herbsleb
  • *Korrespondierende/r Autor/-in für diese Arbeit

Publikation: Beiträge in Zeitschriften › Zeitschriftenaufsätze › Forschung › Begutachtung

Abstract

The implementation of different hypertension thresholds (e.g. ESC/ESH: 140:90 or ACC/AHH: 130:80) substantially increased hypertension prevalence donation of pharmacological treatment across various populations. Under narrow margins of only 10mmHg, measurement accuracy and reliability become decisive for clinical decision-making. However, detailed information on systematic and random errors naturally occurring in clinical practice under repeated testing conditions remain widely limited. To provide practically relevant insights, 65 participants were recruited for visited the lab four times with one un-standardized arrival measurement to mimic oftentimes observed clinical real-world scenarios followed by four standardized measurements performed in adherence with current guidelines. Tests were performed with two certified blood pressure devices, each on two testing days to quantify intra- and interday, as well as interdevice measurement errors via relative reliability and systematic and random measurement errors. Insufficient pre-measurement rest periods caused clinically relevant systematic blood pressure enhancements. Within a subsequent 10–18 min rest, the blood pressure was reliably reduced with about 10 mmHg on both days and both devices. However, the Boso Medicus testing device showed consistently higher blood pressure values with 13mmHg compared to the Welch Allyn monitor. Although measurements could be replicated inter-day in both devices, substantial interdevice discrepancies and clinically relevant random errors were observed, that can cause false-positive hypertension diagnoses, especially when pre-measurement rest was insufficient. Results underscore the relevance of performing several blood pressure assessments (per day and on different days) to account for random measurement errors and reduce the risk of inappropriate clinical decision-making and unnecessary treatment escalation.

OriginalspracheEnglisch
Aufsatznummer593
ZeitschriftBMC Cardiovascular Disorders
Jahrgang26
Ausgabenummer1
Seitenumfang15
DOIs
PublikationsstatusErschienen - 12.2026

Bibliographische Notiz

Publisher Copyright:
© The Author(s) 2026.

Fachgebiete und Schlagwörter

  • Gesundheitswissenschaften

ASJC Scopus Sachgebiete

  • Kardiologie und kardiovaskuläre Medizin

Fingerprint

Untersuchen Sie die Forschungsthemen von „Reliability and device objectivity in oscillatory blood pressure measurement – a measurement error analysis to inform clinical decision making“. Zusammen bilden sie einen einzigartigen Fingerprint.

Dieses zitieren